Chapter 2 Analog Input
E Series User Manual 2-4 ni.com
–10 to +10 V
–5 to +5 V
–2.5 to +2.5 V
–1 to +1 V
–500 to +500 mV
–250 to +250 mV
–100 to +100 mV
–50 to +50 mV
0.5
1
2
5
10
20
50
100
Bipolar 4.88 mV
2.44 mV
1.22 mV
488 μV
244 μV
122 μV
48.8 μV
24.4 μV
4.88 mV
2.44 mV
1.22 mV
488 μV
244 μV
122 μV
48.8 μV
24.4 μV
305 μV
153 μV
76.3 μV
30.5 μV
15.3 μV
7.63 μV
3.05 μV
1.53 μV
4.88 mV
2.44 mV
1.22 mV
488 μV
244 μV
122 μV
48.8 μV
24.4 μV
4.88 mV
2.44 mV
1.22 mV
488 μV
244 μV
122 μV
48.8 μV
24.4 μV
Table 2-2. Input Ranges for NI 6011E and NI 6030E/6031E/6032E/6033E
Input Range Gain Polarity
Precision
NI 6011E
NI 6030E/6030E/
6032E/6033E
0 to +10 V
0 to +5 V
0 to +2 V
0 to +1 V
0 to +500 mV
0 to +200 mV
0 to +100 mV
1
2
5
10
20
50
100
Unipolar 153 μV
76.3 μV
15.3 μV
1.53 μV
153 μV
76.3 μV
30.5 μV
15.3 μV
7.63 μV
3.05 μV
1.53 mV
–10 to +10 V
–5 to +5 V
–2 to +2 V
–1 to +1 V
–500 to +500 mV
–200 to +200 mV
–100 to +100 mV
1
2
5
10
20
50
100
Bipolar 305 μV
153 μV
30.5 μV
3.05 μV
305 μV
153 μV
61.0 μV
30.5 μV
15.3 μV
6.10 μV
3.05 μV
Table 2-1. Input Ranges for NI 6020E, NI 6040E, NI 6052E, NI 6062E, and NI 6070E/6071E (Continued)
Input Range Gain Polarity
Precision
NI 6020E NI 6040E NI 6052E NI 6062E
NI 6070E/
6071E