Chapter 7 Digital Routing
© National Instruments Corporation 7-5 E Series User Manual
Figure 7-2. Connecting Timing Signals
Routing Signals in Software
Table 7-1 lists the basic functions you can use to route signals.
Note For more information about routing signals in software, refer to the NI-DAQmx Help
or the LabVIEW 8.x Help.
Table 7-1. Functions For Routing Signals.
Language Program Function
LabVIEW NI-DAQmx DAQmx Export Signal.vi and
DAQmx Connect Terminals.vi
Traditional NI-DAQ (Legacy) Route Signal.vi
C NI-DAQmx Export_Signal and
DAQmx_Connect_Terminals
Traditional NI-DAQ (Legacy) Select_Signal