Chapter 6 Pole Place Synthesis
© National Instruments Corporation 6-3 Xmath Interactive Control Design Module
where
d
p
(s)=s
n
+ a
1
s
n–1
+ a
2
s
n–2
+...+a
n
n
p
(s)=b
0
s
n
+ b
1
s
n–1
+...+ab
n
Notice that the order of the plant is n, and allow the possibility that the plant
transfer function is not strictly proper; that is, the plant can have as many
zeros as poles.
Normal Mode
In normal mode, the order (number of poles) of the controller is fixed and
equal to n (the order of the plant), so there are a total of 2n closed-loop
poles. In this case, the 2n degrees of freedom in the closed-loop poles
exactly determine the controller transfer function, which also has 2n
degrees of freedom.
In normal mode, the controller transfer function has order n and is strictly
proper:
C(s)=n
c
(s)/d
c
(s)
where
d
c
(s)=s
n
+ x
1
s
n–1
+ x
2
s
n–2
+...+x
n
n
c
(s)=y
1
s
n–1
+ y
2
s
n–2
+...+2y
n
Therefore, the closed-loop characteristic polynomial has degree 2n:
where λ
1
, …, λ
2n
are the closed-loop poles chosen by the user.
χ s() n
c
s()n
p
s() d
c
s()d
p
s()+=
s λ
1
()s λ
2
()s λ
2n
()=
s
2n
α
1
s
2n 1
…α
2
n+++()=